09-24-2022, 08:27 AM | #11 |
Gone Wild
Join Date: Oct 2012
Location: Southwestern Pa.
Posts: 6,214
|
Re: HV Relay trip
I have my upper cell HV relay set to trip (and stop charging) should any given cell reach 4.1V.
I charged it a few days ago but I still got the one cell.....Cell #1....to"trip" the HV relay....thus not giving me my "wanted" full 57V pack charge. So, I'm going to set the upper cell limit to 4.15 and see if I can bump the total pack charge to 57V without that one cell causing the HV relay trip. I'm still going to leave the balancing at the "Dynamic" setting so it brings that #1 cell in balance with the others. I don't see any harm in this as I'm still below the upper 4.2VPC limit. |
|
Thread Tools | |
Display Modes | |
|
Similar Threads | ||||
Thread | Forum | |||
Relay coil fault-relay DNC | Electric Club Car | |||
Glamis trip | Events and Places to ride |