Re: Identify The Wires (Alltrax Upgrade)
Both of the Solenoid big posts are Positive, but yes, it goes on the side where the pack positive battery cable is connected.
You also connect the band/stripe side of the Regen diode on that same post.
The 10ga black wire goes to Controller B-, it is the negative wire from charger receptacle.
Put the pack negative cable first on Controller B-, then place the other negative wires on top.
On Controller B+ put the motor cable first and then the cable from Solenoid on top.
|