Re: 2010 Precedent not doing anything!
No, you have to either replace the OBC or bypass and purchase a smart charger like a Lester Summit II. The powerdrive charger will not function correctly without the OBC. It will have to be monitored and turned off manually. If the charger still works as is now, just remove the jumper and plug the harness back up and charge it normally. Then you can rejumper if needed after charging.
To permanently bypass the OBC, take the two (2) black 10g wires that are at the OBC and cut them loose and butt splice them together. Then jump the Blue and White wires at the carts harness again. You are now bypassed and can run your smart charger. The grey wire will not be used after the Powerdrive use is discontinued.
|